There are a number of different accessories available to complement the 6000 product line.
| 6081 |
8-Ch Screw Terminal Adapter |
 |
6000-001-xx |
Filter Plug-In 6013, 6014, 6018, 6032, 6033* |
| 6082 |
8-Ch RJ45 Adapter |
6000-002 |
Calibration Resistors, 0.01% tolerance |
| 6083 |
8-Ch BNC Adapter |
6000-003 |
Cable, 10', 6028 to BNC |
| 6084 |
8-Ch Thermocouple Reference, 2m Cable |
6000-004-xx |
Filter Plug-in (6028)* |
| 6084-EC |
Additional Cable (per meter) |
6000-005-xx |
Filter Plug-in, Dual (6030)* |
| 6095 |
USB Hard Drive Data Recorder |
6010-RM |
Rack Mounting Tabs for 6010 |
| PS1 |
IES Power Supply, 28 VDC, 1 Amp |
PANEL60 |
Calibration & Maintenance Software |
*Designate Filter Frequency, i.e. 6000-001-11 is 10Hz
 |
6081 Termination Board
Screw terminal
input board.
Includes a temperature
reference that
with a 6013 may
be used for thermocouple
cold junction
compensation but
with less accuracy
than the 6084 below. |
 |
6082 Strain Gage Termination Board
RJ45 Connectors for
8-wire, 120 or 350
Ohm, ¼, ½ and full,
bridge transducers
without changing
completion
components or
jumpers. Uses
8-wire, shielded
Category 5 (Ethernet)
cable. |
 |
6005-001 Interface Connector Panel
Numerous connector
panels are available
for the 6005/6006
to support various
input connections
and specific input
connector types. |
TOP |
 |
 |
6084 Thermocouple Termination
An isothermal, thermocouple termination that with the 6013 input
module provides cold-junction compensation. Compensation is provided
for types B,C,E,J,K,N,R,S, and T thermocouples.
Thermocouple wire attaches to screw terminals. Shorted and open
thermocouple detection is provided and there are terminals for a
user installed passive low-pass filter. A 2 meter cable is provided
connecting to the 6013. |
TOP |
 |
6000-001 Filter Plug-In
Frequency module for low-pass filters. Used on
models with single filter frequency to select bandwidth. |
 |
TOP |
 |
 |
6095 Hard Drive Data Recorder
6000 Systems with the USB interface can have a data recording hard drive
for each enclosure. Data being acquired is simultaneously output on the
USB interface and recorded to an 80 GB hard drive or a solid-state drive with
capacity up to 16GB. This capability
may be used as a backup to computer hard drive recording and will continue
acquiring data in the event of computer or interface failure. It may
also be used as an autonomous recorder. Data is retrieved using the USB
interface in the same multiplexed format as recorded. |
TOP |
 |
PANEL60 Calibration & Maintenance Software
PANEL60 is used for testing, troubleshooting and calibrating
Series 6000 input and output modules.. It automatically maps
a Series 6000 system identifying each input module type and
location. Individual channels on each module may be selected
and programmed for excitation, gain, filter frequency and operating
mode. A scope display monitors the channel output and
excitation.
Learn more about PANEL60 Calibration & Maintenance Software for Series 6000 Data Acquisition Systems.
|
 |
|