  Model 6068 - 2-Channel Transducer Amplifier-Digitizer 300 Volts Common Mode
2-Channel Transducer Amplifier-Digitizer - 300 CMV
Model 6068

6068 Features

  Plug-in module configures channel for multiple transducer types and calibration modes
  Voltage & current excitation with remote sensing
  Isolated excitation and input
  300 Volts common mode
  Gains 1 to 5,000
  100 kHz bandwidth, 200K samples per second
  Voltage and shunt calibration
  High-level analog outputs

6068 Description

The 6068 is a two-channel signal conditioning amplifier-digitizer module featuring 100 kHz bandwidth and both digitized and analog outputs. The base board contains both constant voltage with remote sensing and constant current programmable excitation supplies, high-bandwidth instrumentation amplifier with programmable step and variable gain, nine-frequency six-pole lowpass filter and dual buffered outputs. A plug-on module configures the base board for multiple types of transducers including voltage, full and partial bridge, voltage output charge (IEPE) and charge output piezoelectric.

The input and excitation are isolated from the outputs, power and control interface. This gives the user complete freedom to ground the input without creating ground loops that introduce noise and offset errors. It also provides up to 300 Volt common mode operating voltage.

The differential instrumentation amplifier has programmable gains from 1 to 5,000 and automatic zero. The two analog outputs and the digitized output may be selected independently for wideband or filtered response. The digital output is provided by a successive approximation ADC at up to 200K samples per second providing excellent time alignment between channels. Voltage substation using an external source that is distributed to all channel inputs provides traceable gain calibration.

6068 Function Cards

The 6068 uses a plug-in module to configure the input of each channel for a particular type of transducer or specific type of calibration. Modules can be easily modified or created to handle special customer requirements. The more popular modules are described here and include those for AC and DC coupled voltage, full and partial bridges, and IEPE or piezoelectric charge.

FC1 Bridge Module Bridge Modules

The bridge input is ten-wire shielded accommodating even the most complex transducer wiring schemes. The base board provides both programmable constant voltage with remote sensing and constant current excitation. Programmable completion is provided on the bridge module for quarter, half and full bridge transducers. Automatic bridge balance accommodates large unbalances without limiting dynamic range or loading the transducer output. It can be used to provide voltage offsets in the hundreds of millivolts for non-bridge transducers such as MEMS and variable capacitance.

The capability is provided for up to four-steps of bipolar resistive shunt calibration or DAC shunt calibration that provides 4096 calibration steps using a single calibration resistor. The FC1 Bridge Module shown has a single step of resistance shunt that can be FC2 IEPE Module applied to either an external bridge arm or strain gage or to the internal completion resistor. This module may also be used to apply low-level voltage inputs, DC coupled, to the instrumentation amplifier on the base board.

IEPE Modules

The IEPE module is for piezoelectric and other transducers with built-in electronics and a voltage output. It provides consent current excitation to the transducer that is programmable from 1 to 20 mA with 26 Volt compliance. The output of the transducer is AC coupled to the input of the instrumentation amplifier on the base board.

FC3 Charge Amplifier Charge Modules

The Charge Amplifier module accepts charge signals from piezoelectric transducers. It has two charge ranges that accommodate most charge transducers and applications. Other customer specified ranges.can be provided. It has programmable time constant that can be made long or short as required and a two frequency four-pole highpass filter between the charge amplifier output and the input to the instrumentation amplifier on the base board. The filter is used to eliminate noise such as cable whip. The filter may be bypassed for quasi-DC measurements.

6068 Ordering Information

6068 Two-channel transducer amplifier, 100 kS/s, requires function card. Quote
6068-FC1 Function card: Bridge, single shunt. Quote
6068-FC2 Function card: IEPE, AC coupled voltage. Quote
6068-FC3 Function card: Charge, piezoelectric. Quote