  Model 6040 - Digital Input/Output

FEATURES

  16 Digital Inputs and Outputs
  Compatible with TTL and CMOS
  Optic Isolated Inputs (6040-2)
  Form C Relay Outputs (6040-2)
  Programmable Glitch Capture
  Self Test Mode
  Input/Output Status Display

DESCRIPTION

The 6040 provides 16 digital inputs and outputs for event recording and generation. The basic version, 6040-1, is compatible with TTL and CMOS logic levels. The 6040-2 has optic isolated inputs and form C relay outputs. It also has a +12 VDC isolated power supply for use with control circuits that activate the isolated optic inputs. The 6040 may be combined with other Series 6000 signal conditioning in turnkey data acquisition and control systems.

State of the inputs is normally captured at the time of sampling. The alternate glitch capture mode gives a true state if a 100 ns or wider pulse occured since the channel was last sampled. Inputs are monitored for up to three alarm conditions. Board locations are provided for the installation of input filter components.

Specifications - Model 6040-1 & 6040-2 Digital Input-Output
Inputs
Number 16
Sampling Programmable using the system sample rates.
Glitch Capture Program enabled to capture events of 100 nS or longer.
Alarms Continuous monitoring for specified bit patterns, consisting of high, low and masked bits, for warning, alarm and general alarm.
Connector 50-pin Type D, Subminiature.
Logic Levels
6040-1 TTL/CMOS. Max input is 5.25 V.
6040-2 Optic isolated, off is less than 1.45 V, on is greater than 3.7 V, input impedance is 360 Ohms. Input protected to ±50 Volts. Isolation is 450 Volts, input to input or input to system power ground.
Outputs
Number 50-socket Type D, Subminiature.
Connector 16-bits, two's complement output.
Logic Levels
6040-1 CMOS. On is +4.8 Volts minimum; off is +0.15 Volts maximum from 1K Ohm source impedance.
6040-2 One set of form C contacts, 2 A at 30 VDC. Maximum voltage is 220 VDC.
Isolated Power (Provided on the 6040-2 only)
Output 12 VDC, ±1%, 1.25 A maximum.
Isolation 750 Volts, DC.