  Model 6032 - 4-Channel Strain Gage / Transducer Amplifier-Digitizer
4-Channel Strain Gage/Transducer Amplifier-Digitizer
Model 6032

FEATURES

  Programmable excitation, remote sensing
  Optional continuous excitation monitoring
  Programmable bridge configuration
  Shunt and voltage calibration
  Automatic zero and balance
  Gains 1 to 5,000 with 0.05% resolution
  20K sample rate, 16-bit resolution
  4-Pole low pass filter
  Option programmable filter
  Continuous analog outputs
  Programmable warnings and alarms

DESCRIPTION

Four high-performance, fully programmable signal conditioning amplifiers for quarter, half and full bridge. Each channel has programmable excitation, autobalance, voltage and shunt calibration, differential instrumentation amplifier, low pass anti-aliasing filter and sample and hold amplifier. High-level outputs are multiplexed to a 16-bit ADC.

Individual excitation regulators with remote sensing make the 6032 ideal for use with long input cables. Using remote sensing excitation voltage can be set and regulated at the transducer. An eight-wire, shielded input has dedicated shunt calibration leads or internal shunt can be selected. Excitation voltage can be measured during calibration or the optional excitation monitor continuously digitizes and samples the excitaion for each channel. The standard filter is a 4-pole, Butterworth with plug-in frequency selection. Optionally available is a programmable, 4-pole Butterworth filter with 10 frequency steps per decade. Each channel has a continuous analog output.

Specifications - Model 6032 4-Channel Strain Gage / Transducer Amplifier-Digitizer
Unless noted, specifications apply to each channel individually
Input Two to eight wires with shield with programmable completion for 120 and 350 Ohm quarter, half and full bridge transducers. Input connector is 50-pin Type D Subminiature.
Excitation 0 to +12 Volts in 1 ±0.1% Volt steps, 50 mA individually set and regulated for each channel. Stability is ±0.01%, line and load regulation are ±0.01% using remote sensing. Calibration mode measures excitation voltage using the amplifier. A short on one channel does not affect other channels.
Excitation Monitor (Option EM) Supplemental channel measures excitation using 16-bit ADC, 0.1% accuracy. Dedicated alarms may be used to automatically detect excitation error.
Balance Automatic to ±0.05% of range ±1 mV. Stability is ±0.01%, ±0.005%/°C. User adjustable balance range.
Input Range ±2 mV to ±10 Volts full scale. Input protected to ±50 Volts.
Calibration Voltage substitution with attenuation of 1, 0.1 and 0.01. Single-step resistive shunt calibration. Shunt calibration may be applied to external gauge arm or internal completion resistor.
Gain Programmable from 1 to 5,000 in 1, 2, 3, 5, 10 steps with ±0.05% accuracy.
Static Accuracy Typically ±0.02% for gains 1 to 1,000 after calibration.
Common Mode 110 dB @ gain 1,000, ±10 Volts, protected to ± 50 Volts.
Bandwidth 5 kHz (-3dB) for gains <1,000, 1 kHz for gains > 1,000.
Filter Four-pole low-pass filter with plug-in modules for 1 Hz to 1 kHz, 10 Hz, Butterworth supplied.
Filter (Option PF) Four-pole, low pass Butterworth, 10 Hz to 1 kHz programmable in 10 Hz steps from 10 to 100 Hz and in 100 Hz steps from 100 to 1 kHz.
Sampling Up to 20K samples per second per channel. Time correlation is ±50 nS.
ADC 16-bits, two's complement output.
Analog Output ±10 Volts full scale, wideband.