  Model 6013 - 8-Channel Thermocouple / Voltage Digitizer

FEATURES

  Thermocouple, DC LVDT or voltage
  Cold junction compensation (with 6084)
  ±12 or ±15 VDC for transducers
  Voltage substitution calibration
  Gains from 1 to 5,000
  Four-pole, low-pass filter
  Continuous outputs
  Simultaneous sampling, 16-bit resolution

DESCRIPTION

Each channel on the 6013 has a programmable gain, differential input instrumentation amplifier, low-pass filter and sample and hold. Sample and hold outputs are multiplexed to a 16-bit analog-to-digital converter. A regulated, bipolar 12 or 15 Volt supply provides power for transducers like DC LVDTs. Each channel's power is fused by a resettable polyswitch. The companion 6084 thermocouple junction box has a precision temperature sensor that when used together with the 6013 performs cold junction referencing.

Specifications - Model 6013 8-Channel Thermocouple / Voltage Digitizer
Unless noted, specifications apply to each channel individually
Thermocouple B, C, E, J, K, N, R, S and T thermocouples. Cold junction reference (6084) supplies 10 mV/°C from 0°K that is digitized as the 9th channel. Accuracy is ±0.25 °C over the range +10° to +50° C (junction box temperature).
DC LVDT ±12 or ±15 VDC, 100 mA per channel or 500 mA per module. Protected by 200 mA resetable fuse. Line and load regulation is 0.1%.
Input 2-wire differential with shield. ±2 mV to ±10 Volts full scale. Input protected to ±50 Volts.
Attenuator ±200 mV to ±200 Volts with optional attenuator. Accuracy is ±0.02%.
Calibration Voltage substitution with attenuation of 1, 0.1 and 0.01.
Gain Programmable from 1 to 5,000 in calibrated steps of 1, 2, 3, 5, 10 ... 5,000 with ±0.05% accuracy plus fine adjustment with 0.05% resolution.
Static Accuracy Typically ±0.02% for gains 1 to 1,000 after calibration.
Common Mode 110 dB @ gain 1,000, ±10 Volts, protected to ± 50 Volts.
Bandwidth and Filter 1 kHz bandwidth. Four-pole low-pass filter with plug-in modules for 4 Hz to 1 kHz, 10 Hz supplied.
Sampling Up to 10k samples per second per channel. Time correlation is ±50 nS channel to channel.
ADC 16-bits, two's complement output.
Analog Output ±3 Volts full scale.