16-Slot Data Acquisition Mainframe
Model 6000

FEATURES

  Up to 128 Channels per Enclosure, Expansion to 4096 Channels
  High Speed IEEE-488 Interface
  Up to 1 Million Samples Per Second
  Optional PCM, IRIG 106 Output
  2 Million Sample Pre & Post Trigger Data Storage
  Built-in Fans and Cable Tray
  Mounts in EIA 310C Cabinet

DESCRIPTION

The 6000 Mainframe has an IEEE-488 interface for control and data output with mounting for 16 input and output modules. It supports up to 31 additional slave enclosures or up to 32,000 channels. A rear mounted fan circulates air to the power supplies and input/output modules. An integral cable tray routes the input and output cables to exit from the rear. All access for channel module installation and service is from the front. The 6000 and 6001 slave have removable doors to facilitate installation and wiring.

Mainframe and slave enclosures that are cabinet mounted should be supported on sturdy mounting rails. A rail set, RAL2, is available from Pacific in sizes that fit most cabinets.

Specifications - Model 6000 Mainframe
Capacity Up to 16 Series 6000 input and output modules.
Data 16-bits, 2's complement, formatted in two bytes, low-byte followed by high-byte.
Sample Rate Programmable with 1 µS resolution up to 1 Million samples per second.
Event Memory 2 Million data words. Overwrites the oldest data until triggered. Trigger stores a specified amount of new data then stops. Any data not overwritten is pre-trigger. Trigger may be by software, alarms, digital input or TTL input.
GPIB Interface IEEE-488.2 with high-speed handshake.
Optional PCM Output Two independent buffered PCM data outputs, IRIG 106, NRZL-L, Class II with two clocks. Output and clocks are RS422. Up to 16 MBits/second.
Power 115 or 230 VAC, ±10%, 47 to 63 Hz, 400 Watts
Environmental 0°C to +50°C operating. Humidity to 95% without condensation. Will withstand normal shipping and handling of laboratory instruments.
Size/Weight 19 inches wide, 14 inches high, 20 inches deep, 60 pounds with full complement of channel modules.
Ordering Information
6000 Mainframe, 16-slot, IEEE-488 data and control interface
6000P Mainframe, 16-slot, IEEE-488 data and control interface, IRIG 106, PCM data output.
6001 Slave enclosure, 16-slot
Options
9000-154 PCMCIA IEEE-488 Interface, Windows 98, NT, 2000
9000-156 PCI IEEE-488 Interface, Windows 98, NT, 2000
PS1 Auxiliary power supply for 6014
©2009 Pacific Instruments | Home | Products | Support | News | About Us | Sitemap